Global luminescence lifetime imaging of thermally activated delayed fluorescence on an auto-phase-locked time-gated microscope

Zece Zhu, Xuewen Shu*

*Corresponding author for this work

Research output: Contribution to journalArticle

Abstract

Luminescence lifetime imaging plays an important role in time-resolved detection of luminescence decay differences in microscopic scale. However, the traditional instruments always require expensive detector such as time-correlated single photon counter, stream camera, or intensified CCDs, limiting their practical applications. Herein, a novel approach for global lifetime imaging was developed based on an auto-phase-locked time-gated luminescence microscopy. By utilizing a common color CCD to photograph a set of time-gated luminescence images at different phase differences between the exciting and detecting, a luminescence lifetime image could be obtained by exponential fitting of the gray level of each pixel to the delay time. Compare to the lifetime imaging based on point-by-point scanning, this is a global lifetime measurement of all the pixels, which consumes much less time in detecting long-lifetimes over microseconds. Besides, this method needs no expensive confocal laser scanning systems, intensified CCDs or complex electronic phase matching control, which greatly simplifies the instrument and decreases the cost. This approach was successfully used for fast luminescence lifetime imaging of two classical TADF molecules, which exhibited obvious lifetime differences in microscopic scale. The temporal resolution of the system could reach a few microseconds, suggesting its extensive applicability for many other molecules with long lifetimes.

Original languageEnglish
Pages (from-to)177-182
Number of pages6
JournalSensors and Actuators, B: Chemical
Volume280
Early online date12 Oct 2018
DOIs
Publication statusPublished - 1 Feb 2019

Fingerprint

Luminescence
Microscopes
Fluorescence
microscopes
luminescence
Imaging techniques
life (durability)
fluorescence
Charge coupled devices
charge coupled devices
Pixels
Scanning
Phase matching
Molecules
pixels
Time delay
Microscopic examination
scanning
Photons
Cameras

Keywords

  • Luminescence lifetime imaging
  • Microscope
  • Thermally activated delayed fluorescence
  • Time-resolved

Cite this

@article{03dd423e00ca483babc37e7b359e4d53,
title = "Global luminescence lifetime imaging of thermally activated delayed fluorescence on an auto-phase-locked time-gated microscope",
abstract = "Luminescence lifetime imaging plays an important role in time-resolved detection of luminescence decay differences in microscopic scale. However, the traditional instruments always require expensive detector such as time-correlated single photon counter, stream camera, or intensified CCDs, limiting their practical applications. Herein, a novel approach for global lifetime imaging was developed based on an auto-phase-locked time-gated luminescence microscopy. By utilizing a common color CCD to photograph a set of time-gated luminescence images at different phase differences between the exciting and detecting, a luminescence lifetime image could be obtained by exponential fitting of the gray level of each pixel to the delay time. Compare to the lifetime imaging based on point-by-point scanning, this is a global lifetime measurement of all the pixels, which consumes much less time in detecting long-lifetimes over microseconds. Besides, this method needs no expensive confocal laser scanning systems, intensified CCDs or complex electronic phase matching control, which greatly simplifies the instrument and decreases the cost. This approach was successfully used for fast luminescence lifetime imaging of two classical TADF molecules, which exhibited obvious lifetime differences in microscopic scale. The temporal resolution of the system could reach a few microseconds, suggesting its extensive applicability for many other molecules with long lifetimes.",
keywords = "Luminescence lifetime imaging, Microscope, Thermally activated delayed fluorescence, Time-resolved",
author = "Zece Zhu and Xuewen Shu",
year = "2019",
month = "2",
day = "1",
doi = "10.1016/j.snb.2018.10.071",
language = "English",
volume = "280",
pages = "177--182",

}

Global luminescence lifetime imaging of thermally activated delayed fluorescence on an auto-phase-locked time-gated microscope. / Zhu, Zece; Shu, Xuewen.

In: Sensors and Actuators, B: Chemical, Vol. 280, 01.02.2019, p. 177-182.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Global luminescence lifetime imaging of thermally activated delayed fluorescence on an auto-phase-locked time-gated microscope

AU - Zhu, Zece

AU - Shu, Xuewen

PY - 2019/2/1

Y1 - 2019/2/1

N2 - Luminescence lifetime imaging plays an important role in time-resolved detection of luminescence decay differences in microscopic scale. However, the traditional instruments always require expensive detector such as time-correlated single photon counter, stream camera, or intensified CCDs, limiting their practical applications. Herein, a novel approach for global lifetime imaging was developed based on an auto-phase-locked time-gated luminescence microscopy. By utilizing a common color CCD to photograph a set of time-gated luminescence images at different phase differences between the exciting and detecting, a luminescence lifetime image could be obtained by exponential fitting of the gray level of each pixel to the delay time. Compare to the lifetime imaging based on point-by-point scanning, this is a global lifetime measurement of all the pixels, which consumes much less time in detecting long-lifetimes over microseconds. Besides, this method needs no expensive confocal laser scanning systems, intensified CCDs or complex electronic phase matching control, which greatly simplifies the instrument and decreases the cost. This approach was successfully used for fast luminescence lifetime imaging of two classical TADF molecules, which exhibited obvious lifetime differences in microscopic scale. The temporal resolution of the system could reach a few microseconds, suggesting its extensive applicability for many other molecules with long lifetimes.

AB - Luminescence lifetime imaging plays an important role in time-resolved detection of luminescence decay differences in microscopic scale. However, the traditional instruments always require expensive detector such as time-correlated single photon counter, stream camera, or intensified CCDs, limiting their practical applications. Herein, a novel approach for global lifetime imaging was developed based on an auto-phase-locked time-gated luminescence microscopy. By utilizing a common color CCD to photograph a set of time-gated luminescence images at different phase differences between the exciting and detecting, a luminescence lifetime image could be obtained by exponential fitting of the gray level of each pixel to the delay time. Compare to the lifetime imaging based on point-by-point scanning, this is a global lifetime measurement of all the pixels, which consumes much less time in detecting long-lifetimes over microseconds. Besides, this method needs no expensive confocal laser scanning systems, intensified CCDs or complex electronic phase matching control, which greatly simplifies the instrument and decreases the cost. This approach was successfully used for fast luminescence lifetime imaging of two classical TADF molecules, which exhibited obvious lifetime differences in microscopic scale. The temporal resolution of the system could reach a few microseconds, suggesting its extensive applicability for many other molecules with long lifetimes.

KW - Luminescence lifetime imaging

KW - Microscope

KW - Thermally activated delayed fluorescence

KW - Time-resolved

UR - http://www.scopus.com/inward/record.url?scp=85054924876&partnerID=8YFLogxK

UR - https://www.sciencedirect.com/science/article/pii/S0925400518318343?via%3Dihub

U2 - 10.1016/j.snb.2018.10.071

DO - 10.1016/j.snb.2018.10.071

M3 - Article

AN - SCOPUS:85054924876

VL - 280

SP - 177

EP - 182

ER -