Mechanism of action of the tetraflex accommodative intraocular lens

James S.W. Wolffsohn, Leon N. Davies, Navneet Gupta, Shehzad A. Naroo, George A. Gibson, Toshifumi Mihashi, Sunil Shah

Research output: Contribution to journalArticle

Abstract

PURPOSE:To investigate the mechanism of action of the Tetraflex (Lenstec Kellen KH-3500) accommodative intraocular lens (IOL). METHODS:Thirteen eyes of eight patients implanted with the Tetraflex accommodating IOL for at least 2 years underwent assessment of their objective amplitude-of-accommodation by autorefraction, anterior chamber depth and pupil size with optical coherence tomography, and IOL flexure with aberrometry, each viewing a target at 0.0 to 4.00 diopters of accommodative demand. RESULTS:Pupil size decreased by 0.62+/-0.41 mm on increasing accommodative demand, but the Tetraflex IOL was relatively fixed in position within the eye. The ocular aberrations of the eye changed with increased accommodative demand, but not in a consistent manner among individuals. Those aberrations that appeared to be most affected were defocus, vertical primary and secondary astigmatism, vertical coma, horizontal and vertical primary and secondary trefoil, and spherical aberration. CONCLUSIONS:Some of the reported near vision benefits of the Tetraflex accommodating IOL appear to be due to changes in the optical aberrations because of the flexure of the IOL on accommodative effort rather than forward movement within the capsular bag.
Original languageEnglish
Pages (from-to)1-5
Number of pages5
JournalJournal of Refractive Surgery
Volume26
Issue number11
DOIs
Publication statusAccepted/In press - 15 Jan 2010

Fingerprint

Intraocular Lenses
Pupil
Aberrometry
Astigmatism
Optical Coherence Tomography
Anterior Chamber
Coma

Bibliographical note

© Slack Incorporated. Republication prohibited elsewhere.

Keywords

  • Tetraflex
  • Lenstec Kellen
  • KH-3500
  • accommodative intraocular lens
  • IOL

Cite this

@article{ea45afec0a9949f1905971f1ce3728be,
title = "Mechanism of action of the tetraflex accommodative intraocular lens",
abstract = "PURPOSE:To investigate the mechanism of action of the Tetraflex (Lenstec Kellen KH-3500) accommodative intraocular lens (IOL). METHODS:Thirteen eyes of eight patients implanted with the Tetraflex accommodating IOL for at least 2 years underwent assessment of their objective amplitude-of-accommodation by autorefraction, anterior chamber depth and pupil size with optical coherence tomography, and IOL flexure with aberrometry, each viewing a target at 0.0 to 4.00 diopters of accommodative demand. RESULTS:Pupil size decreased by 0.62+/-0.41 mm on increasing accommodative demand, but the Tetraflex IOL was relatively fixed in position within the eye. The ocular aberrations of the eye changed with increased accommodative demand, but not in a consistent manner among individuals. Those aberrations that appeared to be most affected were defocus, vertical primary and secondary astigmatism, vertical coma, horizontal and vertical primary and secondary trefoil, and spherical aberration. CONCLUSIONS:Some of the reported near vision benefits of the Tetraflex accommodating IOL appear to be due to changes in the optical aberrations because of the flexure of the IOL on accommodative effort rather than forward movement within the capsular bag.",
keywords = "Tetraflex, Lenstec Kellen, KH-3500, accommodative intraocular lens, IOL",
author = "Wolffsohn, {James S.W.} and Davies, {Leon N.} and Navneet Gupta and Naroo, {Shehzad A.} and Gibson, {George A.} and Toshifumi Mihashi and Sunil Shah",
note = "{\circledC} Slack Incorporated. Republication prohibited elsewhere.",
year = "2010",
month = "1",
day = "15",
doi = "10.3928/1081597X-20100114-04",
language = "English",
volume = "26",
pages = "1--5",
journal = "Journal of Refractive Surgery",
issn = "1081-597X",
publisher = "Slack Incorporated",
number = "11",

}

Mechanism of action of the tetraflex accommodative intraocular lens. / Wolffsohn, James S.W.; Davies, Leon N.; Gupta, Navneet; Naroo, Shehzad A.; Gibson, George A.; Mihashi, Toshifumi; Shah, Sunil.

In: Journal of Refractive Surgery , Vol. 26, No. 11, 15.01.2010, p. 1-5.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Mechanism of action of the tetraflex accommodative intraocular lens

AU - Wolffsohn, James S.W.

AU - Davies, Leon N.

AU - Gupta, Navneet

AU - Naroo, Shehzad A.

AU - Gibson, George A.

AU - Mihashi, Toshifumi

AU - Shah, Sunil

N1 - © Slack Incorporated. Republication prohibited elsewhere.

PY - 2010/1/15

Y1 - 2010/1/15

N2 - PURPOSE:To investigate the mechanism of action of the Tetraflex (Lenstec Kellen KH-3500) accommodative intraocular lens (IOL). METHODS:Thirteen eyes of eight patients implanted with the Tetraflex accommodating IOL for at least 2 years underwent assessment of their objective amplitude-of-accommodation by autorefraction, anterior chamber depth and pupil size with optical coherence tomography, and IOL flexure with aberrometry, each viewing a target at 0.0 to 4.00 diopters of accommodative demand. RESULTS:Pupil size decreased by 0.62+/-0.41 mm on increasing accommodative demand, but the Tetraflex IOL was relatively fixed in position within the eye. The ocular aberrations of the eye changed with increased accommodative demand, but not in a consistent manner among individuals. Those aberrations that appeared to be most affected were defocus, vertical primary and secondary astigmatism, vertical coma, horizontal and vertical primary and secondary trefoil, and spherical aberration. CONCLUSIONS:Some of the reported near vision benefits of the Tetraflex accommodating IOL appear to be due to changes in the optical aberrations because of the flexure of the IOL on accommodative effort rather than forward movement within the capsular bag.

AB - PURPOSE:To investigate the mechanism of action of the Tetraflex (Lenstec Kellen KH-3500) accommodative intraocular lens (IOL). METHODS:Thirteen eyes of eight patients implanted with the Tetraflex accommodating IOL for at least 2 years underwent assessment of their objective amplitude-of-accommodation by autorefraction, anterior chamber depth and pupil size with optical coherence tomography, and IOL flexure with aberrometry, each viewing a target at 0.0 to 4.00 diopters of accommodative demand. RESULTS:Pupil size decreased by 0.62+/-0.41 mm on increasing accommodative demand, but the Tetraflex IOL was relatively fixed in position within the eye. The ocular aberrations of the eye changed with increased accommodative demand, but not in a consistent manner among individuals. Those aberrations that appeared to be most affected were defocus, vertical primary and secondary astigmatism, vertical coma, horizontal and vertical primary and secondary trefoil, and spherical aberration. CONCLUSIONS:Some of the reported near vision benefits of the Tetraflex accommodating IOL appear to be due to changes in the optical aberrations because of the flexure of the IOL on accommodative effort rather than forward movement within the capsular bag.

KW - Tetraflex

KW - Lenstec Kellen

KW - KH-3500

KW - accommodative intraocular lens

KW - IOL

UR - http://www.scopus.com/inward/record.url?scp=77950163850&partnerID=8YFLogxK

U2 - 10.3928/1081597X-20100114-04

DO - 10.3928/1081597X-20100114-04

M3 - Article

VL - 26

SP - 1

EP - 5

JO - Journal of Refractive Surgery

JF - Journal of Refractive Surgery

SN - 1081-597X

IS - 11

ER -