Repeatability and agreement of five imaging systems for measuring anterior segment parameters in healthy eyes

  • Mukesh Kumar*
  • , Rohit Shetty
  • , Chaitra Jayadev
  • , Harsha L. Rao
  • , Debarun Dutta
  • *Corresponding author for this work
    • Narayana Nethralaya Eye Hospital

    Research output: Contribution to journal › Article › peer-review

    50   Link opens in a new tab Citations (SciVal)
    68 Downloads (Pure)

    Abstract

    Purpose: The purpose of this study is to assess the repeatability and agreement of five imaging devices, namely, the Pentacam (Oculus), Sirius (CSO), Orbscan IIz (Bausch and Lomb), Corvis (Oculus), and ultrasound pachymetry (UP, Tomey) in measuring steep keratometry (sKm), flat keratometry (fKm), central corneal thickness (CCT), thinnest corneal thickness (TCT), and anterior chamber depth (ACD) in healthy individuals. Design: This was prospective, comparative study. Subjects: Forty-six healthy Indian patients. Materials and Methods: Forty-six eyes of 46 healthy participants underwent three consecutive scans on each device by a single examiner. Within-subject standard deviation, test-retest repeatability (TRT), and coefficient of variation (COV) for assessing repeatability and Bland-Altman plots for the agreement between the mean measurements of each machine were analyzed. Main Outcome Measures: The repeatability and agreement between the five devices for the measurements of sKm, fKm, CCT, TCT, and ACD. Results: The TRT of sKm measurements ranged between 0.23 diopter (D) (with Pentacam) and 0.83 D (with Orbscan). The same of fKm, TCT, ACD, and CCT measurements ranged between 0.28 D (with Pentacam) and 0.74 D (with Sirius), 7.78 μm (Sirius) and 19.81 μm (Orbscan), 0.05 mm (Orbscan) and 0.07 (Sirius), and 7.36 μm (Sirius) and 18.02 μm (Orbscan), respectively. The TRT of sKm and fKm measurements with Pentacam was significantly lower than those with Orbscan and Sirius. The TRT of TCT measurement with Sirius was significantly lower than that with Pentacam (4.53 μm) and Orbscan (7.15 μm). There were statistically significant differences in the mean measurements of all parameters between the devices. The 95% limit of agreement on the Bland-Altman analysis was wide for the measurement pairs with all the devices. Significant proportional bias in the agreement was detected for TCT measurements with all the device pairs and for the ACD measurements between Sirius and Pentacam. Conclusions: The repeatability estimates of sKm, fKm, TCT, ACD, and CCT measurements with Pentacam, Orbscan, Sirius, Corvis, and UP in Indian eyes were good. However, the differences in the measurements between the devices were statistically significant and the same cannot be used interchangeably for anterior segments measurements.

    Original languageEnglish
    Pages (from-to)288-294
    Number of pages7
    JournalIndian journal of ophthalmology
    Volume65
    Issue number4
    DOIs
    Publication statusPublished - 17 May 2017

    Bibliographical note

    Creative Commons Attribution Non-Commercial Share Alike License. Kumar M, Shetty R, Jayadev C, Rao HL, Dutta D.
    Repeatability and agreement of five imaging systems for measuring anterior segment parameters in healthy eyes. Indian J Ophthalmol 2017;65:288-94.

    Keywords

    • Central corneal thickness
    • instruments
    • keratometry

    Fingerprint

    Dive into the research topics of 'Repeatability and agreement of five imaging systems for measuring anterior segment parameters in healthy eyes'. Together they form a unique fingerprint.

    Cite this