The measurement of intraocular pressure over positive soft contact lenses by rebound tonometry

Fabrizio Zeri*, Mario de Cusatis, Luigi Lupelli, Peter Graham Swann

*Corresponding author for this work

Research output: Contribution to journalArticle

Abstract

Purpose - To investigate if the accuracy of intraocular pressure (IOP) measurements using rebound tonometry over disposable hydrogel (etafilcon A) contact lenses (CL) is affected by the positive power of the CLs.
Methods - The experimental group comprised 26 subjects, (8 male, 18 female). IOP measurements were undertaken on the subjects’ right eyes in random order using a Rebound Tonometer (ICare). The CLs had powers of +2.00 D and +6.00 D. Measurements were taken over each contact lens and also before and after the CLs had been worn.
Results - The IOP measure obtained with both CLs was significantly lower compared to the value without CLs (t test; p < 0.001) but no significant difference was found between the two powers of CLs.
Conclusions - Rebound tonometry over positive hydrogel CLs leads to a certain degree of IOP underestimation. This result did not change for the two positive lenses used in the experiment, despite their large difference in power and therefore in lens thickness. Optometrists should bear this in mind when measuring IOP with the rebound tonometer over plus power contact lenses.
Original languageEnglish
Pages (from-to)182–188
Number of pages7
JournalJournal of Optometry
Volume9
Issue number3
Early online date21 Oct 2015
DOIs
Publication statusPublished - Jul 2016

Fingerprint

Hydrophilic Contact Lens
Manometry
Intraocular Pressure
Contact Lenses
Hydrogel
Lenses

Bibliographical note

© 2016 Spanish General Council of Optometry. Published by Elsevier España, S.L.U. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/bync-nd/4.0/).

Keywords

  • contact lens
  • hydrogel
  • intraocular pressure
  • rebound tonometry

Cite this

Zeri, Fabrizio ; de Cusatis, Mario ; Lupelli, Luigi ; Swann, Peter Graham. / The measurement of intraocular pressure over positive soft contact lenses by rebound tonometry. In: Journal of Optometry. 2016 ; Vol. 9, No. 3. pp. 182–188.
@article{e6a218b577d04fa69fc8ca0a19eb4b84,
title = "The measurement of intraocular pressure over positive soft contact lenses by rebound tonometry",
abstract = "Purpose - To investigate if the accuracy of intraocular pressure (IOP) measurements using rebound tonometry over disposable hydrogel (etafilcon A) contact lenses (CL) is affected by the positive power of the CLs.Methods - The experimental group comprised 26 subjects, (8 male, 18 female). IOP measurements were undertaken on the subjects’ right eyes in random order using a Rebound Tonometer (ICare). The CLs had powers of +2.00 D and +6.00 D. Measurements were taken over each contact lens and also before and after the CLs had been worn.Results - The IOP measure obtained with both CLs was significantly lower compared to the value without CLs (t test; p < 0.001) but no significant difference was found between the two powers of CLs.Conclusions - Rebound tonometry over positive hydrogel CLs leads to a certain degree of IOP underestimation. This result did not change for the two positive lenses used in the experiment, despite their large difference in power and therefore in lens thickness. Optometrists should bear this in mind when measuring IOP with the rebound tonometer over plus power contact lenses.",
keywords = "contact lens, hydrogel, intraocular pressure, rebound tonometry",
author = "Fabrizio Zeri and {de Cusatis}, Mario and Luigi Lupelli and Swann, {Peter Graham}",
note = "{\circledC} 2016 Spanish General Council of Optometry. Published by Elsevier Espa{\~n}a, S.L.U. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/bync-nd/4.0/).",
year = "2016",
month = "7",
doi = "10.1016/j.optom.2015.09.001",
language = "English",
volume = "9",
pages = "182–188",
journal = "Journal of Optometry",
issn = "1888-4296",
publisher = "Spanish Council of Optometry",
number = "3",

}

The measurement of intraocular pressure over positive soft contact lenses by rebound tonometry. / Zeri, Fabrizio; de Cusatis, Mario; Lupelli, Luigi; Swann, Peter Graham.

In: Journal of Optometry, Vol. 9, No. 3, 07.2016, p. 182–188.

Research output: Contribution to journalArticle

TY - JOUR

T1 - The measurement of intraocular pressure over positive soft contact lenses by rebound tonometry

AU - Zeri, Fabrizio

AU - de Cusatis, Mario

AU - Lupelli, Luigi

AU - Swann, Peter Graham

N1 - © 2016 Spanish General Council of Optometry. Published by Elsevier España, S.L.U. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/bync-nd/4.0/).

PY - 2016/7

Y1 - 2016/7

N2 - Purpose - To investigate if the accuracy of intraocular pressure (IOP) measurements using rebound tonometry over disposable hydrogel (etafilcon A) contact lenses (CL) is affected by the positive power of the CLs.Methods - The experimental group comprised 26 subjects, (8 male, 18 female). IOP measurements were undertaken on the subjects’ right eyes in random order using a Rebound Tonometer (ICare). The CLs had powers of +2.00 D and +6.00 D. Measurements were taken over each contact lens and also before and after the CLs had been worn.Results - The IOP measure obtained with both CLs was significantly lower compared to the value without CLs (t test; p < 0.001) but no significant difference was found between the two powers of CLs.Conclusions - Rebound tonometry over positive hydrogel CLs leads to a certain degree of IOP underestimation. This result did not change for the two positive lenses used in the experiment, despite their large difference in power and therefore in lens thickness. Optometrists should bear this in mind when measuring IOP with the rebound tonometer over plus power contact lenses.

AB - Purpose - To investigate if the accuracy of intraocular pressure (IOP) measurements using rebound tonometry over disposable hydrogel (etafilcon A) contact lenses (CL) is affected by the positive power of the CLs.Methods - The experimental group comprised 26 subjects, (8 male, 18 female). IOP measurements were undertaken on the subjects’ right eyes in random order using a Rebound Tonometer (ICare). The CLs had powers of +2.00 D and +6.00 D. Measurements were taken over each contact lens and also before and after the CLs had been worn.Results - The IOP measure obtained with both CLs was significantly lower compared to the value without CLs (t test; p < 0.001) but no significant difference was found between the two powers of CLs.Conclusions - Rebound tonometry over positive hydrogel CLs leads to a certain degree of IOP underestimation. This result did not change for the two positive lenses used in the experiment, despite their large difference in power and therefore in lens thickness. Optometrists should bear this in mind when measuring IOP with the rebound tonometer over plus power contact lenses.

KW - contact lens

KW - hydrogel

KW - intraocular pressure

KW - rebound tonometry

UR - http://www.scopus.com/inward/record.url?scp=84951066981&partnerID=8YFLogxK

UR - https://www.clinicalkey.com/#!/content/playContent/1-s2.0-S1888429615000783?returnurl=https:%2F%2Flinkinghub.elsevier.com%2Fretrieve%2Fpii%2FS1888429615000783%3Fshowall%3Dtrue&referrer=https:%2F%2Fpure.aston.ac.uk%2Fadmin%2Feditor%2Fdk%2Fatira%2Fpure%2Fapi%2Fshared%2Fmodel%2Fresearchoutput%2Feditor%2Fcontributiontojournaleditor.xhtml%3Fid%3D19572057

U2 - 10.1016/j.optom.2015.09.001

DO - 10.1016/j.optom.2015.09.001

M3 - Article

AN - SCOPUS:84951066981

VL - 9

SP - 182

EP - 188

JO - Journal of Optometry

JF - Journal of Optometry

SN - 1888-4296

IS - 3

ER -