Theoretical fitting characteristics of typical soft contact lens designs

Anna Sulley*, Kathrine Osborn-Lorenz, James S. Wolffsohn, Graeme Young

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

Abstract

Purose: To calculate theoretical fitting success rates (SR) for a range of typical soft contact lens (SCL) designs using a mathematical model. Method: A spreadsheet mathematical model was used to calculate fitting SR for various SCL designs. Designs were evaluated using ocular topography data from 163 subjects. The model calculated SR based on acceptable edge strain (within range 0-6%) and horizontal diameter overlap (range 0.2-1.2. mm). Where lenses had multiple base curves (BCs), eyes unsuccessful with the steeper BC were tested with the flatter BC and aggregate SR calculated. Calculations were based on typical, current, hydrogel and silicone hydrogel SCLs and allowed for appropriate on-eye shrinkage (1.0-2.3%). Theoretical results were compared with those from actual clinical trials. Results: Theoretical success rates for one-BC lenses ranged from 60.7% (95% CI 7.2%) to 90.2% (95% CI 3.7%). With two-BC designs, most combinations showed a SR increase with a second BC (84.0%-90.2%). However, one of the two-BC combinations showed only negligible increase with a second BC (72.4%-73.0%). For designs with lower SR, the greatest contributor to failure was inadequate lens diameter. For a given design, differences in shrinkage (i.e. on-eye bulk dehydration) had a significant effect on success rate. In comparison with historical clinical data, there was a positive correlation between small lens fitting prevalence and discomfort reports (r. = + 0.95, P = <. 0.001) with a poor correlation between theoretical and actual tight/loose fittings. Conclusions: Mathematical modelling is a useful method for testing SCL design combinations. The results suggest that judicious choice of additional fittings can expand the range of fitting success.

Original languageEnglish
Pages (from-to)248-252
JournalContact Lens and Anterior Eye
Volume40
Issue number4
Early online date11 May 2017
DOIs
Publication statusPublished - 1 Aug 2017

Bibliographical note

© 2017, Elsevier. Licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International http://creativecommons.org/licenses/by-nc-nd/4.0/

Keywords

  • base curve radius
  • corneal coverage
  • diameter
  • soft contact lens
  • success rate
  • tightness

Fingerprint

Dive into the research topics of 'Theoretical fitting characteristics of typical soft contact lens designs'. Together they form a unique fingerprint.

Cite this