Clinical comparison of optimum and large diameter soft contact lenses

James S. Wolffsohn, Lee Hall, Graeme Young

Research output: Contribution to journalArticlepeer-review

Abstract

Purpose To compare the clinical performance of large diameter lenses with optimally fit lenses in the same material and monocurve back surface design. Method In a four-visit, randomised, bilateral, crossover, study, 25 myopic subjects wore optimum diameter lenses (control) and large diameter lenses (test) in random succession for 1 week each. Both study lenses were made of methafilcon A and of an identical design. Trial fittings with Frequency 55 (Coopervision) lenses modified with a design algorithm were used to determine the appropriate custom-made study lenses. Results The least squares mean scores (±SE) for overall comfort and end-of-day comfort (0–10 scale) were 7.57 ± 0.33 vs. 7.42 ± 0.33 (P = 0.59) and 7.00 ± 0.31 vs. 7.27 ± 0.32 (P > 0.05) for the optimum and large diameter lenses, respectively. There were no significant differences in mean (±SE) gradings for limbal hyperaemia (1.23 ± 0.11 vs. 1.19 ± 0.11, 0–4 scale, P = 0.60) and corneal staining (1.79 ± 0.25 vs. 2.04 ± 0.25, P = 0.39). Conjunctival staining was greater for the optimum lens: 1.80 ± 0.28 vs. 0.93 ± 0.28 (0–4 scale, P = 0.001). With regard to lens fit, the large diameter lenses showed significantly less post-blink movement (0.22 ± 0.01 vs. 0.16 ± 0.01 mm, P = 0.004), and greater total decentration (0.15 ± 0.02 vs. 0.21 ± 0.02 mm, P = 0.010). However, there was no significant difference in the key fit variable of tightness on push-up (46 ± 0.69% vs. 48 ± 0.69%, 0–100 scale, P = 0.12). Discussion The findings suggest that larger than optimal soft lenses may be worn without detriment to either comfort or ocular physiology, provided an optimal fit is otherwise maintained.
Original languageEnglish
Pages (from-to)405-411
Number of pages7
JournalContact Lens and Anterior Eye
Volume41
Issue number5
Early online date5 May 2018
DOIs
Publication statusPublished - 1 Oct 2018

Bibliographical note

© 201X, Elsevier. Licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International http://creativecommons.org/licenses/by-nc-nd/4.0/

Keywords

  • Soft contact lens
  • Diameter
  • Base curve radius
  • Tightness
  • Corneal coverage

Fingerprint

Dive into the research topics of 'Clinical comparison of optimum and large diameter soft contact lenses'. Together they form a unique fingerprint.

Cite this