Comparison of subjective and objective methods to determine the retinal arterio-venous ratio using fundus photography

Rebekka Heitmar*, Angelos A. Kalitzeos, Sunni R. Patel, Diana Prabhu-Das, Robert P. Cubbidge

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

Abstract

Purpose: To assess the inter and intra observer variability of subjective grading of the retinal arterio-venous ratio (AVR) using a visual grading and to compare the subjectively derived grades to an objective method using a semi-automated computer program. Methods: Following intraocular pressure and blood pressure measurements all subjects underwent dilated fundus photography. 86 monochromatic retinal images with the optic nerve head centred (52 healthy volunteers) were obtained using a Zeiss FF450+ fundus camera. Arterio-venous ratios (AVR), central retinal artery equivalent (CRAE) and central retinal vein equivalent (CRVE) were calculated on three separate occasions by one single observer semi-automatically using the software VesselMap (ImedosSystems, Jena, Germany). Following the automated grading, three examiners graded the AVR visually on three separate occasions in order to assess their agreement. Results: Reproducibility of the semi-automatic parameters was excellent (ICCs: 0.97 (CRAE); 0.985 (CRVE) and 0.952 (AVR)). However, visual grading of AVR showed inter grader differences as well as discrepancies between subjectively derived and objectively calculated AVR (all p < 0.000001). Conclusion: Grader education and experience leads to inter-grader differences but more importantly, subjective grading is not capable to pick up subtle differences across healthy individuals and does not represent true AVR when compared with an objective assessment method. Technology advancements mean we no longer rely on opthalmoscopic evaluation but can capture and store fundus images with retinal cameras, enabling us to measure vessel calibre more accurately compared to visual estimation; hence it should be integrated in optometric practise for improved accuracy and reliability of clinical assessments of retinal vessel calibres.

Original languageEnglish
Pages (from-to)252-257
Number of pages6
JournalJournal of Optometry
Volume8
Issue number4
Early online date26 Jul 2014
DOIs
Publication statusPublished - Oct 2015

Bibliographical note

© 2014, Elsevier. Licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International http://creativecommons.org/licenses/by-nc-nd/4.0/

Keywords

  • arterio-venous ratio
  • central retinal artery equivalent
  • central retinal vein equivalent
  • reproducibility
  • retinal vessel diameter
  • semi-automated analysis
  • visual grading

Fingerprint

Dive into the research topics of 'Comparison of subjective and objective methods to determine the retinal arterio-venous ratio using fundus photography'. Together they form a unique fingerprint.

Cite this