Targets and self monitoring in hypertension: randomised controlled trial and cost effectiveness analysis

R.J. McManus, J. Mant, A. Roalfe, R.A. Oakes, S. Bryan, Helen M. Pattison, F.D. Richard Hobbs

Research output: Contribution to journalArticlepeer-review

Abstract

OBJECTIVES: To assess whether blood pressure control in primary care could be improved with the use of patient held targets and self monitoring in a practice setting, and to assess the impact of these on health behaviours, anxiety, prescribed antihypertensive drugs, patients' preferences, and costs. DESIGN: Randomised controlled trial. SETTING: Eight general practices in south Birmingham. PARTICIPANTS: 441 people receiving treatment in primary care for hypertension but not controlled below the target of < 140/85 mm Hg. INTERVENTIONS: Patients in the intervention group received treatment targets along with facilities to measure their own blood pressure at their general practice; they were also asked to visit their general practitioner or practice nurse if their blood pressure was repeatedly above the target level. Patients in the control group received usual care (blood pressure monitoring by their practice). MAIN OUTCOME MEASURES: Primary outcome: change in systolic blood pressure at six months and one year in both intervention and control groups. Secondary outcomes: change in health behaviours, anxiety, prescribed antihypertensive drugs, patients' preferences of method of blood pressure monitoring, and costs. RESULTS: 400 (91%) patients attended follow up at one year. Systolic blood pressure in the intervention group had significantly reduced after six months (mean difference 4.3 mm Hg (95% confidence interval 0.8 mm Hg to 7.9 mm Hg)) but not after one year (mean difference 2.7 mm Hg (- 1.2 mm Hg to 6.6 mm Hg)). No overall difference was found in diastolic blood pressure, anxiety, health behaviours, or number of prescribed drugs. Patients who self monitored lost more weight than controls (as evidenced by a drop in body mass index), rated self monitoring above monitoring by a doctor or nurse, and consulted less often. Overall, self monitoring did not cost significantly more than usual care (251 pounds sterling (437 dollars; 364 euros) (95% confidence interval 233 pounds sterling to 275 pounds sterling) versus 240 pounds sterling (217 pounds sterling to 263 pounds sterling). CONCLUSIONS: Practice based self monitoring resulted in small but significant improvements of blood pressure at six months, which were not sustained after a year. Self monitoring was well received by patients, anxiety did not increase, and there was no appreciable additional cost. Practice based self monitoring is feasible and results in blood pressure control that is similar to that in usual care.
Original languageEnglish
Pages (from-to)493
Number of pages1
JournalBMJ
Volume331
Issue number7515
DOIs
Publication statusPublished - 22 Aug 2005

Keywords

  • blood pressure control
  • primary care
  • patient held target
  • self monitoring
  • health behaviours
  • anxiety
  • prescribed antihypertensive drugs
  • preferences
  • costs

Fingerprint

Dive into the research topics of 'Targets and self monitoring in hypertension: randomised controlled trial and cost effectiveness analysis'. Together they form a unique fingerprint.

Cite this